About Local Programming
Local Programming Features
Linking Mode Readies the module for linking to another INSTEON device. As linking is directional, the rst device placed
into linking mode will become the controller in the controller/responder relationship. The second device will
become the responder. The device automatically exits linking mode after a link has been made with another
INSTEON device or four minutes have elapsed without linking.
Multi-Linking
Mode
Readies the module for linking to multiple INSTEON devices. The module will remain in linking mode for 4
minutes or until the module’s set button is tapped. This mode is very usefully for manually creating scenes.
Unlinking
Mode
Allows the removal of links from the INSTEON device. The device will automatically exit unlinking mode after a
link has been removed from another INSTEON device or four minutes have elapsed without linking.
Multi-
Unlinking
Mode
Allows the removal of multiple links from the INSTEON device. The device will stay in unlinking mode for 4
minutes or until the device’s set button is tapped.
LED
Brightness
Allows adjusting the brightness level of the module’s status LED.
RF Beacon Places the device in a mode that broadcasts a signal over INSTEON RF. Any devices beeping or displaying a
blinking LED are within range of the module’s RF signal.
Factory Reset Erases any user-customized programming from the device including all INSTEON device links, scenes, ramp
rate, on-level, etc. A factory reset cannot be undone.
To move right, press and
hold the set button
To move down, tap the set
button
Status LED blinks green
Status LED double-blinks
green
Status LED blinks red
Status LED double-blinks
red
The Local Programming Flowchart is a visual
representation of the device’s settings. Many
device features can be congured using this
diagram. Some devices have more options
than others but the Local Programming
Flowchart presents even the most
complicated devices with a straightforward,
navigable path.
If using the INSTEON Hub or any other
central controller, it is strongly advised that
you not use Local Programming. Your central
controller can manage the device properties
and links for you.
Navigation Local Programming
Using a Central Controller
NEW