Page 9 of 27 Rev: 1/21/2014 8:36 AM
Note: The start of one program mode is also the end of the previous program mode.
Third press of Program:
Cool setpoint
Up/Down arrows cycle through temperature
Press and hold scrolls through temperatures
Fourth press of Program:
Heat setpoint
Up/Down arrows cycle through temperature
Press and hold scrolls through temperatures
Fifth press of Program:
Restarts the process to program another Mode/Day.
NOTE: The four modes come preprogrammed. The defaults are for all days:
Day
Modes
Start Time
Thermostat
Mode
Heat
Setting
Cool
Setting
Wake 6:00AM Auto 65°F 18°C 75°F 24°C
Leave 8:30AM Auto 60°F 16°C 80°F 27°C
Return 5:00PM Auto 65°F 18°C 75°F 24°C
Sleep 11:00PM Auto 60°F 16°C 80°F 27°C
Note: To exit program setup mode, press Mode button once.
Fan and Hold Button Operations
Fan button operations
The Fan button is only functional when INSTEON Wireless Thermostat is linked to an INSTEON
Thermostat
The Fan button cycles between Auto and Always On
On the display, it simply indicates the text “Fan Always” when selected. There is no text for Auto.