0

Out of 0 Ratings

Owner's of the Whistler Marine Battery PRO-400W gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 15
 
2120
TROUBLESHOOTING
TROUBLESHOOTING
PROBLEM: Low Battery Alarm On All The Time
Problem Solution
Input voltage below Keep input voltage above
10.5 volts. 10.5 volts to maintain
regulation.
Poor or weak battery Replace battery
.
condition.
Inadequate power being Use lower gauge wire.
delivered to the inverter (400 watt model)
or excessive voltage drop.
Red LED On
Problem Solution
Equipment has a high Turn inverter power switch
start up surge. OFF (O) and then ON (l)
again until the inverter
powers your appliance.
Repeat as necessary
to get your appliance
"started".
Battery voltage below Recharge or replace
10 volts. battery.
Equipment being operated Use a higher capacity
draws too much power. inverter.
Inverter is too hot (thermal Allow inverter to cool.
shutdown mode). Check for adequate
ventilation. Reduce the
load on the inverter to
rated continuous power
output.
PROBLEM: TV Interference
Problem Solution
Electrical interference from Add a Ferrite data line filter
inverter. on to the TV power cord.
This filter is available at
electronic part stores.
.
PROBLEM: Low or No Output Voltage
Problem Solution
Using incorrect type of Use a
true RMS reading
voltmeter to test output meter.
voltage. See "For You Technical
Types" Section of this
manual.
Please visit our Inverter FAQ page on our website
(www. .com), for more troubleshooting
information and FYI topics.
pro200-400w.qxp 4/30/2010 9:07 AM Page 23