0

Out of 0 Ratings

Owner's of the ADTRAN Network Router Adtran Netvanta Modular Access Router gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 90
 
Option Modules NetVanta 3200/3300/3400 Series
48 Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB
NetVanta T1/FT1 + DSX-1 NIM (P/N 1202863L1)
The NetVanta T1/FT1 + DSX-1 NIM (shown in Figure 19) provides a full T1 or fractional T1 network
interface and a DSX-1 interface. See Table A-7 on page 87 for the WAN-T1 connector pinouts, Table A-9
on page 88 for the DSX-1 connector pinouts, and Table A-15 on page 91 for the DBU connector pinouts.
An optional DIM is required for dial backup applications.
Figure 19. NetVanta T1/FT1 + DSX-1 NIM
WAN-T1 DSX-1 DBU
Features and Specifications
Operating Modes
Frame Relay, multilink Frame Relay
PPP, MLPPP
HDLC
T1/FT1 Interface
Supported Standards: AT&T TR 62411,
AT&T TR 65016, ANSI T1.403,
Bellcore TR 194
Line Rate: 1.544 Mbps +
75 bps
Line Code: AMI or B8ZS
Framing: D4 (SF) or ESF
FT1 Line Rate: DS0 channelized (multiples
of 56/64 kbps)
Input Signal: 0 to -36 dB (DS1)
Line Build Out: 0, -7.5, -15, -22.5 dB
(long), 0 to 655 ft. (short)
DS0 Assignment: Programmable
Connector: RJ-48C
DSX-1 Interface
Line Interface: DSX-1 per ANSI T1.102
DSX Receiver Input Range: -10 dBdsx to
+6 dBdsx
Line Rate: 1.544 Mbps
Capacity: 1 to 24 DS0s
Line Codes: AMI, B8ZS
DSX-1 Interface to PBX
Framing: D4 (SF) or ESF
Line Length: 0 to 655 feet and -7.5 dB
Connector: RJ-48C
Clock Source
•Network
Internal
Through
Diagnostics
Test Pattern Generation and Detection:
511, QRSS, all ones, all zeros
Network loopbacks (local and remote);
responds to inband and FDL loop codes (T1
interface only)
Alarm generation and detection
Network and user sets of performance data
(15 minutes and 24 hours)
Compliance
EMC - see Electromagnetic Compatibility
(EMC) Table on page 6.
ACTA/FCC Part 68
IC CS-03
UL/CUL 60950-1
Environmental
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent,
noncondensing
Physical
Dimensions: 2.75-inch W x 4.25-inch D