of 90
 
Unit Installation NetVanta 3200/3300/3400 Series
70 Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB
Powering the NetVanta 3205 (AC), NetVanta 3305, NetVanta 3430, NetVanta 3448,
NetVanta 3450, and NetVanta 3458
The AC-powered NetVanta 3205, NetVanta 3305, NetVanta 3430, NetVanta 3448, NetVanta 3450, and
NetVanta 3458 come equipped with an auto-sensing 100 to 250 VAC, 50/60 Hz power supply for
connecting to the proper power receptacle. A grounded, three-plug detachable cable is included with the
shipment.
Powering the NetVanta with Octal PoE Upgrade
The NetVanta PoE Power Supply is an auto-sensing 100 to 250 VAC, 50/60 Hz power supply for
connecting to the proper power receptacle. This power supply is only available with the Octal PoE
Upgrade bundle for the NetVanta 3448 and the NetVanta 3458, which include the power supply and the
Octal PoE module. A grounded, three-plug detachable cable is included with the shipment.
This unit shall be installed in accordance with Articles 300 and 400 of NEC NFPA 70.
Power to the AC system must be from a grounded 100 to 250 VAC, 50/60 Hz source.
Maximum recommended ambient operating temperature is 50
o
C.
This unit shall be installed in accordance with Articles 300 and 400 of NEC NFPA 70.
Power to the AC system must be from a grounded 100 to 250 VAC, 50/60 Hz source.
Maximum recommended ambient operating temperature is 50
o
C.
The NetVanta PoE Power Supply is intended
to supply up to 8 PoE ports at 48 VDC, 15.4 watts per port.
to be installed, maintained, and serviced by qualified service personnel only.
for use only with NetVanta units with the Octal PoE Upgrade module installed.
Before powering your NetVanta with the PoE Power Supply, the Octal PoE Upgrade
module must first be installed. Refer to Installing the Octal PoE Upgrade Module on
page 81 for more information.
The NetVanta PoE Power Supply should be installed in a restricted access location
as described in UL 60950-1.
Under full load, the NetVanta PoE Power Supply may be hot to the touch.