MODEL EI5936SS
Page 9
LIGHT BULBS
LAMP SOCKET
BRACKET
SCREWS
LIGHT
PANEL
MAKE-UP AIR DAMPER
The hood is compatible with Broan Make-Up Air Damper Model MD6T or
Model MD8T (optional). Purchase separately.
Make the connection to the Make-Up Air Damper with low voltage
wiring, as shown. See Make-Up Air Damper instructions for additional
information.
REMOTE CONTROL
The hood is compatible with Broan Radio Frequency (RF) Remote
Control Model BCR1 (optional). Purchase separately.
To link the BCR1 remote control with the hood, press and hold the LIGHT
button for 3-seconds.
The blue LED indicators will turn on and off in succession to indicate the
hood is in RF linking mode. When in the linking mode, press any key on
the RF remote. An audible beep will be heard at the hood, and the hood
LED’s will stop blinking if a successful link is accomplished. If the remote
control did not successfully link with the hood, the linking mode will be
deactivated after 12 seconds, and the LED’s will stop the sequential
blinking. Refer to the BCR1 instructions for additional information.
CLEANING & MAINTENANCE
For performance, appearance, and health reasons, clean filter, fan and
grease-laden surfaces. Use only a clean cloth and mild detergent solution
on stainless and painted surfaces. Clean all-metal filters in the dishwasher
using a non-phosphate detergent. Discoloration of the filter may occur if
using phosphate detergents, or as a result of local water conditions - but
this will not affect filter performance. This discoloration is not covered by
the warranty. Clean the non-duct recirculating filter surfaces frequently
with a damp cloth and a mild detergent. DO NOT immerse filters in
water or put in dishwasher. Change the non-duct recirculating filters
every 6 months. For replacement non-duct recirculating filters - purchase
S99010365 or Model FILTERE56. The motor is permanently lubricated
and never needs oiling. If the motor bearings make excessive or unusual
noise, replace the blower assembly with an exact service replacement.
(1)
PUSH IN
(2)
ROTATE
CLOCKWISE
SUCTION CUP TOOL
HALOGEN
BULB
MAKE-UP AIR DAMPER
HOOD
24V
TRANSFORMER
(INCLUDED)
GRD
DRY CONTACT
TERMINAL
BUSHING
FOR LOW
VOLTAGE
CONNECTION
MODEL EW56, EW58, EI59 SERIES
MAKE UP DAMPER CONNECTION
(switched low voltage)
20 GAUGE BELL WIRE FOR LOW
VOLTAGE CONNECTION ON
TOP OF HOOD
120 VAC
60 HZ
WARNING
Bulbs may be hot. Always allow bulbs to cool down before removing
them.
Use (2) Halogen Bulbs (included with hood) - 120 V, 35 W, shielded
halogen bulbs - MR16 with GU10 base.
NOTE
Suction Cup Tool (included with hood) can be used to install and
remove light bulbs. Align pins on bulb with large diameter opening
on socket, then push bulb in towards hood and rotate clockwise until
firmly seated. The position of the bulb socket (depth) is adjustable and
may require adjustment when: a) certain brands of bulbs are difficult to
install. b) the bulb protrudes too far below the light panel.
To change the depth of bulb sockets:
- Remove 2 screws on light panelset screws aside
- Remove Light Panel.
- Loosen 2 Screws holding Lamp Socket Bracket to Light Panel.
- Adjust socket/bracket to desired depth.
- Re-tighten screws securely.
- Re-attach light panel with 2 screws that were previously set aside.